Gold Member Since 2010
Audited Supplier
Qingdao Kingworld Control Co., Ltd.

Retard Chamber, Tyco Retard Chamber, Retard Chamber for Variable Pressure Wet Pipe Sp manufacturer / supplier in China, offering Tyco Wet Pipe Sprinkler Systems Retard Chamber, Colorful BMX Bicycle Tyre/Tire 24X1.95, 26X1.95, 24X2.125, 26X2.125, Malaysia Price Motorcycle Inner Tube 3.00-17 3.00-18 90/90-17 130/90-15 and so on.

(/ )

Supplier Homepage Product Control Fire Tyco Wet Pipe Sprinkler Systems Retard Chamber

Tyco Wet Pipe Sprinkler Systems Retard Chamber

FOB Price: US $5-30 / Piece
Min. Order: 100 Pieces
Min. Order FOB Price
100 Pieces US $5-30/ Piece
Get Latest Price
Port: Qingdao, China
Production Capacity: 50000 Per Year
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: RC-1
  • Sprinkler Head Type: Open
  • Automatically Opened and Closed Repeatedly: Can′t Automatically Opened and Closed
  • Closed Fire Sprinkler System: Wet Fire Sprinkler System
  • Wet Alarm Valve Structure: Seat Type
  • Nozzle Flow Coefficient: 80
  • Working Water Pressure: 300 Psi (20,7 Bar)
  • Approvals: UL cUL FM
  • Warranty: 10-Year Limited Warranty
  • Trademark: Tyco
  • Specification: 1, 1 1/4 inch NPT
  • Sprinkler Installation: Ordinary
  • Alarm Valve Type: Wet Alarm Valve
  • Open Fire Sprinkler System Type: Water Spray System
  • Dry Alarm Valve Type: Differential Type
  • Alarm Valve Diameter: 80mm
  • Deluge Valve Type: Diaphragm Type
  • Body Material: Cast Iron
  • Connection: Thread
  • Product Name: Tyco Wet Pipe Sprinkler Systems Retard Chamber
  • Transport Package: as Customer Require
  • Origin: China
Product Description


Tyco Wet Pipe Sprinkler Systems Retard Chamber

Model RC-1 Retard Chamber For Variable Pressure Wet Pipe Sprinkler Systems 300 psi (20,7 bar) 

General    Description
The Tyco® Model RC-1 Retard Chamber is required in installations that will be subject to pressure variations, as are generally associated with public water supplies, in order to help prevent false alarms. The RC-1 is specifically intended for use as a separately ordered item for the Model AV-1-300 Alarm Check Valve (TFP910). It can, however, also be used as a separately ordered item for changing out older style Retard Chambers used with the Central Model F/G, Gem Model A, or Star Model E/F Alarm Check Valves. 

The Model RC-1 Retarding Chamber is a re-designation for the Gem Model F211 for use with Gem Model F20/ F200/F2001 Alarm Check Valves, as well as the Star Model S310 for use with Star Model S30/S300/S3001 Alarm Check Valves.


Technical  Data
Approvals
UL and ULC Listed, as well as FM Approved for use with the Model AV-1-300 Alarm Check Valves

UL and ULC Listed, as well as FM, LPCB, and VdS Approved for use with the following Alarm Check Valves:

    Model AV-1-175 Gem 
    Model F20/F200/F2001 Gem 
    Model A Star 
    Model S30/S300/S3001

Working Water Pressure 
300 psi (20,7 bar)

Construction 
The Model RC-1 Retard Chamber shown in Figure 1 is cast iron, and a 3/4" x 1/2" x 3/4" Tee is provided at the outlet (top) for connection of a pressure alarm switch and/or water motor alarm. The Restriction Assembly shown in Figure 2 is provided with the AV-1-300 trim or ordered separately for retrofitting other valves. This assembly is comprised of brass restrictions assembled to a cast iron or malleable iron threaded tee fitting. The screen is stainless steel. 


Operation 

When water flows steadily into the sprinkler system due to sprinkler operation, the Waterway Clapper in the Alarm Check Valve opens as shown in Figure 3. Water is then permitted to flow into the centrally located groove in the Seat Ring and out through the Alarm Port towards the Restriction Assembly. 

When the flow through the Inlet Restriction of the Restriction Assembly exceeds the flow out through the Outlet Restriction, the Retard Chamber begins to fill. Subsequently, the Water Motor Alarm and/or the Pressure Alarm Switch activate. The alarms continue to operate as long as the Waterway Clapper remains open. When the Clapper closes as a result of discontinued water flow, water in the alarm lines automatically drains out through the 1/8 inch (3,2 mm) drain orifice in the Restriction Assembly. In the case of variable pressure systems, a transient surge in supply pressure that is sufficient only to open the Clapper momentarily will not cause a false alarm. The volume of the Retard Chamber is sufficiently large enough that it will not fill to operate the connected alarm devices. Any water in the alarm line is then automatically drained, further reducing the possibility of a false alarm due to a successive transient surge in supply pressure. 

Technical Data
ApprovalsUL ULC FM
Working Water Pressure300 psi
Construction3/4"*1/2"*3/4" Tee is provided of the outlet for connecion of a pressure alarm switch and water motor alarm